  • Moisture range: 3~35%
  • Working temperature: 0~40C
  • Refund will be given as: Money Back
  • Weight: 1kg
  • Test error: ≤0.5%.
  • Power supply: 9V DC, 4pcs dry batterie
  • Sample weight: 150g
  • Repeat error: ≤2%.
  • Return shipping will be paid by: Seller
  • Custom Bundle: Yes
  • Item must be returned within: 30 Days
  • Brand: Unbranded
  • Restocking Fee: No
  • MPN: Does Not Apply
  • Test time: 10s
  • Working humidity: ≤80%
  • All returns accepted: Returns Accepted

    Description

    Store category
    Sign Up Now !
    You may also like
    Grains Rice Wheat Maize Moisture Testing LDS-1G Grain Computer Moisture Meter US
    Product Description
    Product Description
    grain moisture meter, seed moisture meter, cereal moisture meter.
    Because of the zone and species difference and the limitation to the pre-established standard species parameters.
    it is possible to find the error when using the default parameters defined by the factory. The customer can use following way to calibrate the error and standard to make sure the precision.
    1) revisory value confirmation:
    Based on the standard samples by means of 105°C over, the corrective value means the standard value minus the test result. For example, the Tested moisture is 13.6% and the actual moisture needed to display is 14%, so we should add 0.4, and the current reviser value is 0.4. Otherwise it will be the negative value.
    2) In revising status:
    Spill the sample from the instrument, press the species key for long time till flash and then loose it. The red.
    lamp under the low left corner of the display will be bright, and the instrument will display the default revisory value "0.0". It means that the instrument is now in the revising status.
    3) revision:
    Press the "+" key to add 0.4, then press the OK key to save. The revision is completed when the lamp flashes.
    Press the species key or switch off to exit.
    The complete procedure refers to following illustration.
    Standard setup:
    If you want to add the measurable species or you can prepare the standard sample by yourself, you can use.
    following way to set up the standard.
    1) Prepare the standard sample: Prepare three kinds of standard samples with high, middle and low moisture by means of 105°C oven (if the actual Test range is less than 6%, it is enough to only use two standard samples with high and low moisture.). In order to make the standard setup representation and veracity, the moisture in the high.
    and low standard sample must be in the two ends of the actual moisture range. The suitable moisture difference among the standard samples is 3-6%. (for examples: the moisture of wheat is 18%, 14% and 10%).
    2) Enter into the standard setup: Spill the sample from the instrument, press the "OK" key for long time and loose it when the display flashes. The red lamp under the low left corner of the display will be bright, and the species code is showed on the display. It indicates that the instrument is now in standard setup.
    3) Select the species code: Press ""or ""key to select the species code.
    4) Note the setup order: You should follow the following order to set standard: first is the low moisture, next is the high moisture and final is the middle moisture.
    5) Set low moisture standard: take low moisture sample and fall them into the sensor. When the test result is displayed, change the Test result (display 11%) into the standard value (10%). Then press "OK" key and loose it till the digits flash. One standard setup is completed.
    For example:
    note: one standard setup can be also the approach to calibrate the error.
    6) Set high moisture standard: Spill the sample but don't switch off the instrument. Again take high moisture sample and fall them into the sensor. When the test result is displayed, change the Test result (display 17%) into the standard value (18%). Then press "OK" key and loose it till the digits flash. Two standards setup is completed.
    7) Test the standard samples again: Test the standard sample again. If the error is equal or less than 0.5%, it indicates the standard setup is successful. Switch off the instrument to exit the standard setup. If the error is large, it needs to reset the standard setup.
    8) The third standard setup: If the gap between the low and high moisture standard sample is too large (exceed the 6%), the middle moisture standard sample can be used as the third standard setup. The setup approach is the same as it used in high and low moisture standard setup.
    Specification:
    Weight: 1kg.
    Specifications.
    Test time: 10s.
    Repeat error: ≤2%.
    Test error: ≤0.5%.
    Sample weight: 150g.
    Grain moisture meter.
    Moisture range: 3~35%.
    Working humidity: ≤80%.
    Temperature compensation.
    Working temperature: 0~40C.
    Test more then 20 kinds of grain.
    Power supply: 9V DC, 4pcs dry batteries.
    Payment
    Delivery details
    Terms of sales
    About us
    Contact us
    Payment
    We accept ebay payment 。
    Fees such as import duties, taxes are not included in the item price or shipping costs. These charges are the buyer's responsibility.
    Delivery details
    Shipping:
    The item will be shipped from our US warehouse to United States, which is more faster than from aboard.
    2-9 working days to: USA
    Terms of sales
    We maintain high standards of excellence and strive for hundred percent customer satisfaction. Feedback is very important to us. We hope that you contact us immediately before you give neutral or negative feedback, so that we can address your concerns. It is impossible to address issues if we do not know about them!
    About us
    Your satis
    faction is our ultimate goal. We work hard to earn your trust and future business. Our certified technicians have tested each item before shipping. The unit comes with 1 year limited warranty on all manufacturing defects.
    a) If you receive a defective item, you may return it or ask for a discount. Please contact us within 14 days after you receive the package.
    b) What you returned must be intact and in its original packaging as re? u. Customer is responsible for shipping costs of the returned item.
    c) We will cover the cost of shipping back t with the shipping rate indicated in the registration page. We will send you a new unit or refund the full payment you paid.
    Thank you.
    Contact us
    Business Hour
    Business Hour: Monday To Friday: 8:30 AM to 5:00 PM (Beijing China time)
    Due to time zones, our reply to your questions may not be immediately. But within above working time, we will reply your email within 24 hours. If it's non-workdays, please kindly be patient and wait till Monday.
    Please contact us with ebay message.
    Please feel free to contact us if you have any questions.
    : Monday To Friday: 8:30 AM to 5:00 PM (Beijing China time)
    Due to time zones, our reply to your questions may not be immediately. But within above working time, we will reply your email within 24 hours. If it's non-workdays, please kindly be patient and wait till Monday.
    Please contact us with ebay message.
    Please feel free to contact us if you have any questions.
    On Jun-29-21 at 02:38:51 PDT, seller added the following information: