-40%
Dental Photo-Activated Disinfection Medical Laser Equipment Oral Laser Treatment
$ 86.05
- Description
- Size Guide
Description
1.1 DESCRIPTIONPhoto-Activated Disinfection technology is based on two components to selectively tag and destroy cariogenic bacteria and periodontal pathogens:
a solution of dilute, pharmaceutical grade tolonium chloride (a vital stain)
and light of a specific wavelength (650 nm) to activate the solution.
Photo-Activated Disinfection(PAD) Light-F3WW provide the light of a specific wavelength (650 nm) to activate the solution.
Introduced into dental hard or soft tissue, the solution of dilute, pharmaceutical grade tolonium chloride (a vital stain) selectively targets and tags all bacteria. When the solution is activated by the Photo-Activated Disinfection(PAD) Light-F3WW,it releases singlet oxygen which ruptures the cell walls of bacteria, killing them in seconds.
1.2 Indications for Use
Photo-Activated Disinfection(PAD) Light-F3WW is equally effective to activate the solution on the bacteria found in root canals, periodontal pockets, periimplantitis,carious teeth,Infection control and pain relief.
Kills all bacteria including:
• Streptococcus mutans
• Total streptococcus
• Streptococcus sobrinus
• Streptococcus intermedius
• Actinomyces
• Lactobacillus
• veilonella
• Prevotella intermedia
• Peptostreptococcus micros
• Fusobacterium nucleatum
• Porphyromonas gingivalis
• Staphaloccoccus aureus
• E.faecalis
2.INSTALLATION
2.1 Product content
The shipping box should contain the following device components:
Description
QTY
PAD Light main body
1
Magnetic rechargeable battery
1
Goggle
2
Light rob
2
Charge station
1
Power Adapter
1
Disposal Tip
20
User Guide
1
2.2 CLEANING AND STERILIZATION BEFORE USE ON PATIENTS
The PAD Light and accessories are provided non-sterile. Cleaning and sterilization of accessories and components that come in contact with open tissue is required prior to use on patients.
2.3 Safety
Do not stare into the visible light. Laser light is emitted from this device. Avoid extreme exposure. Do not point the device at anyone’s eyes.
2.4 BATTERY CHARGING
The device will need to be fully charged prior to the first use. Plug the AC recharging power cord into the unit and then into the wall socket. Charge for at least 12 hours before the first use.
Recharge the device at least once every 3 weeks whether you have used the device or not.
Put battery into the cylinder of the the charge station ( Contact PCB faces down), the green light turns on when it’s charging, the light will turn off when the battery get full charge. It’s about 2 hour to get full charge.
3. OPERATING INSTRUCTIONS
1.Push the Power/Select Button to power on the light.
2.Push the Power/Select Button to select the seconds for the procedure.
3.Push the Light Button to activate the Light.
4.Push the Light Button to stop the light.
When the light is activated,there is a “bee” tone in every 30seconds.
Note:The light will be turned off after 3 mins without any operation.
Pull out the battery to stop the power.
4.WARNINGS
•Because the device contains a laser, do not shine it directly into your eyes or look directly at the laser light. Do not point the PAD Light device at your or another person’s eyes.
• The safety of laser devices on pregnant women has not been established.
• Avoid use of the PAD Light device over, or in the area of, cancerous lesions.
• The device should not be used during the following activities:
• bathing or showering
• sleeping
• driving or operating machinery
5.MAINTENANCE
Like any electronic product, the PAD Light requires proper care and handling. The following is recommended:
• Do not drop the device or handle it roughly.
• Do not immerse the device in water or any liquid.
• If using the device on more than one person, sterilization of light rob for each use.
6.Technical Specification
Wavelength
650nm ± 5nm
Power
200mw
Diameter
18.5mm
Weight:
1100g
Length without a light rod
102mm
Magnetic Rechargeable Battery:
Lithium Ion
Diameter of the out put of the light rod
6mm
Power supply
3DV rechargeable batteries
Button control
Sound signalisation
Magnet coupled rechargeable batteries
Continuous model of the laser beam
FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Seller name:
baistrastore
City,State:SHENZHEN,China
Telephone number:0755-66587533
Contact Us
If you have any questions, please contact us via ebay message system
:
)
Please believe that our commitment and ability, positive feedback is not our goal, bring you a better experience is our common goal indeed.
Payment
We accept PayPal only
.
The address in your paypal details will be used as the actual shipping adress, please make sure the adress is correct.
If you are planning on combining your items, please make sure that you wait until ALL auctions have ended before you visit the checkout. All items must be paid within 7 days.
Shopping
The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events).
General shipping time is between 7-12 working days.
Some remote areas of Europe shipping time is around 15-25 days, and South America shipping will be more then 25 days.
(After the shipping started, the order will be monitored and the track of the item will be posted on paypal).
Destination
Delivery Time
Working Days
7-12
10-15
15-25
25-40
>50
US
Item arrived
80%
10%
8%
1%
Refund
ASIA
Item arrived
30%
40%
20%
10%
Refund
EU
Item arrived
20%
20%
50%
10%
Refund
AU
Item arrived
30%
30%
20%
20%
Refund
Other Countries
Item arrived
5%
10%
10%
60%
--
Returns
Exchanges are offered for items that are defective or damaged when received, although this is highly unlikely. After exchanges are made and have not resolved the issue, we will refund the cost of the merchandise..
Defective items or problems with your order must be reported within 3 days after receiving. Please keep all packaging, documentation, packing list, etc. that came with your order. These will be used to verify claims if there is any problem with you.
Restocking fee will be charged for returned items without original package or any quality problem.Please contact us for details before returning your package to avoid misunderstanding.
[IMPORTANT]: Customer's item must be returned to our facility with the ROF (Return Order Form) at the buyers shipping expense.
About Us
We are one of the biggest dental products suppliers in China, which focus on manufacturing and selling high quality dental equipments, dental materials and carrying a full line of high quality products, like KAVO, NSK, WOODPECKER, ets.
We supply many kinds of dental Handpieces, Ultrasonic scalers, Light cure, Endodontics Instruments, Micro motor, Dental Leb Equipment, Orthodontics and dental consumables ect.
All our products are manufactured under the strict quality contorl guidelines established by ISO 9001:2000 international standard quality certification, most of them have FDA and CE certificate.